Information that applies to all sensors
bello network monitoring offers a wide range of sensor
types to monitor many different aspects of a network device. When creating and
editing sensors there are special parameters for each sensor type and there are
also some parameters that are available for all sensors.
The following parameters are common to all sensors:
· Associated
Server—use the drop-down menu to select a server to which to attach this
sensor
·
Name—enter a descriptive name for the sensor
·
Comments—enter a description for the sensor (i.e., what it does or
when it will check)
·
Status—use the drop-down menu to set the status of the sensor.
Options include
· Active
· Paused
(disables monitoring for a sensor)
·
Schedule – allows you to select a schedule defined under My
Account (See Managing Schedules). From the
drop-down menu you can select from the defined schedules.
·
Interval—use the drop-down menu to select an available interval.
·
Notifications (see Managing
Notifications for details)
· On
Error—use the drop-down to select if this level of notification is on and
what bello network monitoring should do
· On
Warning—use the drop-down to select if this level of notification is on and
what bello network monitoring should do
· On
OK—use the drop-down to select if this level of notification is on and what
bello network monitoring should do
· On
Escalation—use the drop-down to select if this level of notification is on
and what bello network monitoring should do
Most sensors also have one or more of the following common
parameters:
·
Timeout—specify a time (in seconds) when the sensor should stop
trying to accomplish its objective and send a failure notification
· Warning
level—specify a time (in seconds) when the response time of the sensor
should generate a warning notification. If you have the On Warning
Notification set to active, this will determine when the notification is
sent.
Please check the following sections for details on the
technology of the various sensor types and for details on the individual
parameters.